Honeywell 802374 Multi-sensor Fire Detector

  • Size: 5.7 x 7.5 x 5.1 in. (14.5 x 19.1 x 13 cm)
  • Weight: 4.2 lb. (1.95 kg)
  • Operating Temp: -40 to 158 F (-40 to 70 C)
  • Ambient Humidity: 5-95% RH Non-Condensing
  • Sensor Type: Fuel Gases: Catalytic Toxic Gases & Oxygen: Electrochemical
  • Input Power: 24 VDC nominal, range 18 to 30 VDC, 0.3 A DC Total Max. 24 VAC nominal, range 12 to 24 VAC, 0.3 A AC Total Max. (AC must not be grounded)
  • Fuse F2 on Main Board: Polyswitch 750 mA Polyswitch device resets after fault is cleared and power to the circuit is removed
  • Relays Three Relays, SPDT, Dry Contacts 1.0 A maximum at 30 VDC (resistive load) 0.3 A maximum at 125 VAC (resistive load)
  • Display LCD: graphic display with backlight
  • Keypad Three Non-Intrusive Magnetic switches – F1, F2, F3
  • Enclosure: Aluminum Pressure Die-Casting Entries: 2 x 3/4 “NPT
  • Certificate: FM 3615, CSA C22.2 No.30 Class I, Groups A, B, C, D, Class II, Groups E, F, G; Class III Enclosure Type: 4X, Division 1 Division 2 ANSI / ISA 12.22.01 Class I, Zone 1 AExd II C, IP66 Zone 1 CSA E60079-1 Ex d II C, Class I, Zone 1, IP66
  • Status Indicators: Five Status LED’s RS-485 TX Status (Green) RS-485 RX Status (Green) Relay 1 Status (Network) Relay 2 Status (Network) Relay 2 Status (Network)

 

 

  • Size: 5.7 x 7.5 x 5.1 in. (14.5 x 19.1 x 13 cm)
  • Weight: 4.2 lb. (1.95 kg)
  • Operating Temp: -40 to 158 F (-40 to 70 C)
  • Ambient Humidity: 5-95% RH Non-Condensing
  • Sensor Type: Fuel Gases: Catalytic Toxic Gases & Oxygen: Electrochemical
  • Input Power: 24 VDC nominal, range 18 to 30 VDC, 0.3 A DC Total Max. 24 VAC nominal, range 12 to 24 VAC, 0.3 A AC Total Max. (AC must not be grounded)
  • Fuse F2 on Main Board: Polyswitch 750 mA Polyswitch device resets after fault is cleared and power to the circuit is removed
  • Relays Three Relays, SPDT, Dry Contacts 1.0 A maximum at 30 VDC (resistive load) 0.3 A maximum at 125 VAC (resistive load)
  • Display LCD: graphic display with backlight
  • Keypad Three Non-Intrusive Magnetic switches – F1, F2, F3
  • Enclosure: Aluminum Pressure Die-Casting Entries: 2 x 3/4 “NPT
  • Certificate: FM 3615, CSA C22.2 No.30 Class I, Groups A, B, C, D, Class II, Groups E, F, G; Class III Enclosure Type: 4X, Division 1 Division 2 ANSI / ISA 12.22.01 Class I, Zone 1 AExd II C, IP66 Zone 1 CSA E60079-1 Ex d II C, Class I, Zone 1, IP66
  • Status Indicators: Five Status LED’s RS-485 TX Status (Green) RS-485 RX Status (Green) Relay 1 Status (Network) Relay 2 Status (Network) Relay 2 Status (Network)

 

 

Reviews

There are no reviews yet.

Be the first to review “Honeywell 802374 Multi-sensor Fire Detector”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Be the first to review “Honeywell 802374 Multi-sensor Fire Detector”

Your email address will not be published. Required fields are marked *